The Sauer-Danfoss 42 Series from LIC Hydraulic is a compact, high-power density axial variable displacement piston pump specifically engineered for closed-circuit hydrostatic drives. Covering displacements from $28\text{cc}$ to $51\text{cc}$ (e.g., 42R28, 42L41, 42R51), these pumps are the industry standard for medium-duty mobile applications. Models like 42R28CE1A503B3C2CNN feature integrated charge pumps and multifunctional control valves. We guarantee 100% mechanical interchangeability and subject every unit to 100% full-load testing to ensure precise control and reliable power delivery.
Technical Specifications (Bulleted List)
Series: Danfoss 42 Series (Closed Circuit)
Displacements: $28\text{ cm}^3\text{/rev}$, $41\text{ cm}^3\text{/rev}$, $51\text{ cm}^3\text{/rev}$
Rated Pressure: $350\text{ bar}$ ($5075\text{ psi}$)
Peak Pressure: $415\text{ bar}$ ($6000\text{ psi}$)
Max Speed: Up to $4000\text{ rpm}$
Control Options: MDC (Manual), EDC (Electric Proportional), HD (Hydraulic)
Rotation: L (CCW) and R (CW) available
Integral Valves: Includes charge relief, high-pressure relief, and bypass valves
Key Technical Advantages
Compact Integration: By housing the main pump, charge pump, and all necessary valves in one unit, the 42 Series minimizes hydraulic plumbing, reduces potential leak points, and significantly simplifies machine assembly.
Smooth Control Response: Equipped with sophisticated displacement control mechanisms (like EDC), the pump provides precise and predictable acceleration and deceleration, critical for the safety and maneuverability of mobile machinery.
Optimized Quiet Operation: The 9-piston rotating group reduces flow ripple and structural vibration. Combined with precision-ground valve plates, it ensures exceptionally low noise levels across the entire operating range.
Reliable Charge Cooling: The built-in charge pump provides continuous cooling flow and maintains system pressure within the closed loop, preventing cavitation and extending the service life of internal components under heavy loads.
Application Areas
Mobile Propulsion: Primary drive pumps for skid steer loaders, rollers, and compact pavers.
Material Handling: Main traction systems for telescopic handlers and rough-terrain forklifts.
Ag-Machinery: Drive systems for harvesters and high-clearance sprayers.
Utility Vehicles: Propulsion and tool drives for municipal sweepers and airport ground support equipment.
Expert Maintenance Tips
Monitor Charge Pressure: Charge pressure is the lifeblood of a closed-circuit pump. Always verify that charge pressure reaches the specified setting (typically $220\text{–}360\text{ psi}$ above case pressure) upon startup to protect the piston shoes.
Maintain Oil Cleanliness: Closed-circuit systems recirculate oil; therefore, debris can cause rapid wear. Use high-efficiency filters and replace them according to the ISO cleanliness standards (target 18/16/13).
Case Pressure Management: Ensure the case drain line is correctly sized and unrestricted. Excessive case pressure (over $2\text{ bar}$/$30\text{ psi}$) will result in shaft seal failure and internal mechanical misalignment.