Danfoss MBC 5180 Pressure Switch | MBS Sensor | 061B129966 061B128166
| Model Number | 061B128066, 061B128166, MBC5180 2031-2DB04 061B129966, MBC5180 |
|---|
Product Description
The Danfoss MBC 5180 Series and MBS Sensors from LIC Hydraulic represent the pinnacle of heavy-duty pressure control. Specifically designed for environments characterized by severe vibration, moisture, and temperature fluctuations, these block-style components—such as 061B129966 and 061B128166—ensure mission-critical reliability. We guarantee 100% original specification compliance and subject every unit to 100% pressure-response accuracy testing and electrical integrity verification, delivering professional stability for marine and industrial hydraulic systems.
Technical Configuration Details
MBC 5180: Marine-certified block-type pressure switch (LR, DNV, GL, BV compliant).
Ordering Codes: 061B129966, 061B128166, 061B128066 (Varying by range, G-thread/NPT options, and electrical connectors).
MBS Functionality: High-stability pressure transmitters providing analog signals for continuous monitoring alongside the switch logic.
Operating Media: Suitable for hydraulic oil, fuel oil, water, and air.
Key Technical Advantages
Extreme Vibration Resistance: The robust block design and internal micro-switch mechanism prevent false triggering in high-vibration applications, such as on-engine mounting for massive diesel units.
Space-Saving Modular Design: The compact footprint allows for direct block mounting, significantly reducing the complexity of piping and fitting within hydraulic manifold assemblies.
Fixed or Adjustable Deadband: Engineered for precision, these switches maintain consistent system pressure, preventing “short cycling” of pumps and reducing wear on hydraulic components.
Industrial & Marine Grade: Built with corrosion-resistant materials and featuring extensive marine certifications, these units are the industry benchmark for offshore and saltwater environments.
Application Areas
Marine Propulsion: Monitoring of lubrication oil, fuel, and cooling water pressure in ship engines.
Heavy Duty HPUs: High-pressure safety cut-offs and automated pump control in industrial power packs.
Air Compressors: Precise inter-stage pressure management for industrial gas compressors.
Wind Turbines: Monitoring hydraulic pressure in pitch and braking control systems.
Expert Installation Tips
Atmospheric Reference: Ensure the atmospheric reference vent on the MBC block remains unobstructed to maintain accuracy in set-point performance.
Electrical Shielding: In high-EMI (Electromagnetic Interference) environments like engine rooms, use shielded cables and ensure the DIN or plug connectors are correctly seated to maintain the IP65/67 rating.
In-Situ Calibration: While factory-set options are available, it is best practice to verify and fine-tune the switching point using a calibrated master gauge during the initial system commissioning to account for local line loss and dynamic pressure peaks.
Related Models:
MBC5100-4241-1CB04
MBC5100-4241-1CB04
061B000066 MBC 5100
061B000166 MBC 5100
061B000266 MBC 5100
061B000366 MBC 5100
061B000466 MBC 5100
061B000566 MBC 5100
061B000766 MBC 5100
061B000966 MBC 5100
061B001066 MBC 5100
061B002966 MBC 5100
061B010066 MBC 5100
061B010266 MBC 5100
061B010366 MBC 5100
061B010466 MBC 5100
061B010566 MBC 5100
061B010966 MBC 5100
061B011066 MBC 5100
061B012866 MBC 5100
061B100066 MBC 5100
061B100166 MBC 5100
061B100266 MBC 5100
061B100366 MBC 5100
061B100466 MBC 5100
061B100566 MBC 5100
061B100766 MBC 5100
061B100866 MBC 5100
061B100966 MBC 5100
061B101766 MBC 5100
061B102366 MBC 5100
061B102466 MBC 5100
061B110066 MBC 5100
061B110266 MBC 5100
061B110366 MBC 5100
061B110466 MBC 5100
061B110566 MBC 5100
061B110766 MBC 5100
061B110866 MBC 5100
061B510066 MBC 5100
061B510166 MBC 5100
061B510266 MBC 5100
061B000066 MBC 5100-1411-1CB04
061B000166 MBC 5100-3421-1CB04
061B000266 MBC 5100-1411-1DB04
061B000366 MBC 5100-3421-1DB04
061B000466 MBC 5100-1211-1DB04
061B000566 MBC 5100-1011-1DB04
061B000766 MBC 5100-2211-1DB04
061B000966 MBC 5100-1011-1CB04
061B001066 MBC 5100-1211-1CB04
061B002966 MBC 5100-2011-1DB04
061B010066 MBC 5100-1411-2CB04
061B010266 MBC 5100-1411-2DB04
061B010366 MBC 5100-3421-2DB04
061B010466 MBC 5100-1211-2DB04
061B010566 MBC 5100-1011-2DB04
061B010966 MBC 5100-1011-2CB04
061B011066 MBC 5100-1211-2CB04
061B012866 MBC 5100-1211-1DB04
061B100066 MBC 5100-3231-1CB04
061B100166 MBC 5100-4241-1CB04
061B100266 MBC 5100-3231-1DB04
061B100366 MBC 5100-4241-1DB04
061B100466 MBC 5100-2431-1DB04
061B100566 MBC 5100-3641-1DB04
061B100766 MBC 5100-3641-1CB04
061B100866 MBC 5100-2431-1CB04
061B100966 MBC 5100-2231-1DB04
061B101766 MBC 5100-2031-1DB04
061B102366 MBC 5100-2031-1CB04
061B102466 MBC 5100-3331-1DB04
061B110066 MBC 5100-3231-2CB04
061B110266 MBC 5100-3231-2DB04
061B110366 MBC 5100-4241-2DB04
061B110466 MBC 5100-2431-2DB04
061B110566 MBC 5100-3641-2DB04
061B110766 MBC 5100-3641-2CB04
061B110866 MBC 5100-2431-2CB04
061B510066 MBC 5100-5251-1CB04
061B510166 MBC 5100-5451-1CB04
061B510266 MBC 5100-5651-1CB04
061B200066 MBC 5000-1411-1CB04
061B200166 MBC 5000-3421-1CB04
061B200266 MBC 5000-1411-1DB04
061B200366 MBC 5000-3421-1DB04
061B200466 MBC 5000-1211-1DB04
061B200566 MBC 5000-1011-1DB04
061B200966 MBC 5000-1011-1CB04
061B201566 MBC 5000-1011-0DB04
061B201666 MBC 5000-1211-0DB04
061B201766 MBC 5000-1211-0DB04
061B208866 MBC 5000-2431-1CB04
061B300066 MBC 5000-3231-1CB04
061B300166 MBC 5000-4241-1CB04
061B300266 MBC 5000-3231-1DB04
061B300366 MBC 5000-4241-1DB04
061B300466 MBC 5000-2431-1DB04
061B300566 MBC 5000-3641-1DB04
061B300666 MBC 5000-3441-1CB04
061B300766 MBC 5000-3641-1CB04
061B300866 MBC 5000-2431-1CB04
061B500066 MBC 5000-5651-1CB04
061B500166 MBC 5000-5451-1CB04
061B500266 MBC 5000-5251-1CB04



Company Profile


Professional Manufacturer