TA1919 Hydraulic Double Pump for Bell 225A Loader | TA1919V10R-12AR05CB21-511
| Model Number | TA1919V10R-12AR05CB21-511 |
|---|
Product Description
The TA1919 Series Double Pump from LIC Hydraulic is a high-performance Hydrostatic Transmission (HST) solution specifically engineered for the Bell 225A Loader. As the heart of the drive system, models like the TA1919V10R-12AR05CB21-511 provide independent flow to the left and right wheel motors, enabling the signature zero-turn agility of Bell tri-wheel loaders. This integrated unit combines two axial piston pumps with a dedicated V10 charge pump, offering a robust, all-in-one power source. Our pumps are 100% drop-in replacements for original Vickers equipment, built to OEM specifications for seamless integration and maximum uptime.
Technical Highlights
Dual Displacement: $41\text{ cm}^3\text{/rev} \times 2$ (Twin 19 Size)
Integral Charge Pump: V10 Vane Pump configuration for loop replenishment.
System Compatibility: Optimized for Bell 225A forestry and agricultural loaders.
Pressure Rating: Continuous $210\text{ bar}$ (3000 psi) with higher peak capacity.
Control: Manual or hydraulic pilot control options available.
Core Advantages
Precision Agility: The dual-pump architecture allows for independent wheel speed control, critical for the maneuverability required in sugarcane and timber loading.
Closed-Loop Reliability: Integrated relief valves and charge system minimize the external components needed, reducing potential leak points and simplifying maintenance.
Heavy-Duty Bearings: Upgraded bearing sets designed to withstand the frequent directional changes and high vibration common in Bell loader operations.
OEM Standard Mounts: Perfectly matches the SAE “B” or custom Bell-specific mounting patterns and shaft splines.
Maintenance Best Practices
Complete System Flush: The most common cause of premature failure is contamination from a previous pump breakdown. You MUST flush the wheel motors and entire loop before installing a new TA1919 pump.
Air Bleeding: Ensure the case is filled with oil prior to startup. Run the loader at low idle for several minutes to bleed air from the control cylinders to ensure smooth response.
Oil Cleanliness: Maintain fluid at ISO 18/15/13 or better. In the dusty environments of Bell loaders, high-quality air breathers and periodic oil analysis are essential for long service life.



Company Profile


Professional Manufacturer